PVC Covered Conductor

Description

Gongniu Cable constructs its PVC Covered Conductors using premium-grade materials to ensure longevity and optimal conductivity. These conductors feature a core of concentrically stranded wires, which can be made from aluminum, copper, aluminum-alloy, or Aluminum Conductor Steel-Reinforced (ACSR). Clients can specify either compressed or uncompressed stranded constructions for their particular needs. A robust Polyvinyl Chloride (PVC) sheath encases the stranded core, offering excellent insulation and protection against environmental factors. We provide this PVC covering in black for Type 8 conductors and in green for Type 16 conductors, facilitating easy identification. The fundamental design of these conductors involves stranded, circular wires for consistent performance.

Application

Our PVC Covered Conductors are engineered for deployment in a variety of overhead power line infrastructures. Gongniu Cable offers two primary types of these conductors, Type 8 and Type 16, to accommodate different operational voltage requirements. Type 8 conductors are intended for use in power line systems where the operating voltage between any two conductors does not surpass 650 volts RMS. These Type 8 conductors are also suitable if the voltage between any single conductor and the earth is 250 volts RMS or less. For applications demanding higher voltage capacities, Type 16 conductors provide a reliable solution. Type 16 is suitable when the operating voltage between any two conductors exceeds 650 volts RMS, or when the voltage between any conductor and the earth surpasses 250 volts RMS. Generally, these Type 16 conductors are utilized in systems where the voltage between conductors does not normally exceed 11 kilovolts RMS, or where the voltage between any conductor and earth does not typically go beyond 6.6 kilovolts RMS.

Specifications

Gongniu Cable manufactures all PVC Covered Conductors in strict accordance with recognized international standards. Our products consistently meet BS 6485, the standard for PVC-Covered Conductors For Overhead Power Lines. Furthermore, they comply with BS EN 50182, which outlines specifications for Conductors For overhead lines — Round Wire Concentric Lay Stranded Conductors. Depending on the chosen conductor material (such as aluminum, copper, or alloys), our products also align with several other key British Standards, including:

  • BS 215-1 for Aluminum Stranded Conductors
  • BS 215-2 for Aluminum Conductors, Steel-Reinforced
  • BS 3242 for Aluminum Alloy Stranded Conductors used in overhead power transmission
  • BS 7884 for Copper and Copper-Cadmium Stranded Conductors intended for overhead electric traction and power transmission systems

Technical Parameter

PVC Covered Conductor BS 6485,BS 251-1 AAC/PVC

Code WordNominal cross-sectional area (mm²)Stranding and Wire Diameter (mm)Approximate Overall Diameter of Bare Conductor (mm)Maximum Resistance per kilometre at 20 °C (Ω)Approximate Breaking Load (kN)Approximate Overall Diameter of Covered Conductor (mm)Approximate Mass per kilometre of Covered Conductor (kg/km)
Type 8Type 8
Midge227/2.066.181.2273.998.2100
Aphis253/3.357.21.0814.119.2133
Gnat257/2.216.631.0664.598.8118
Weevil303/3.667.90.90824.8610.1158
Mosquito357/2.597.770.77626.0310.0156
Ladybird407/2.798.370.66896.8710.6177
Ant507/3.109.300.54198.2811.7200
Fly607/3.4010.20.45059.9012.4249
Bluebottle707/3.6611.00.388111.3413.2285
Earwing757/3.7811.30.364411.9413.6302
Grasshopper807/3.9111.70.340612.7813.9319
Clegg907/4.1712.50.299414.5314.7359
Wasp1007/4.3913.170.270216.0016.0360
Beetle10019/2.6713.40.270417.4215.6387
Bee1257/4.9014.70.216919.9416.9482
Cricket1507/5.3616.10.181323.8518.3567
Hornet15019/3.2516.30.182527.7018.5538
Caterpillar17519/3.5317.70.154728.6319.9646
Chafer20019/3.7818.90.134932.4021.7690
Spider22519/3.9920.00.121136.0122.2809
Cockroach25019/4.2221.10.108340.4023.3900
Butterfly30019/4.6523.30.0891648.7025.51082
Moth35019/5.0025.00.0771156.3727.21241
Drone35037/3.5825.10.0774157.4527.31222
Locust40019/5.3626.80.067164.7329.01416
Centipede40037/3.7826.50.0694463.1028.71353
Maybug45037/4.0928.60.0593174.0130.81573
Scorpion50037/4.2729.90.0544179.9832.11706
Cicada60037/4.6532.60.0458894.9534.82010
Tarantula75037/5.2336.60.03627120.1038.82519

PVC Covered Conductor BS 6485,BS 215-2 ACSR/PVC

Nominal cross-sectional area (mm²)Stranding and Wire Diameter (No./mm)Approximate Overall Diameter of Bare Conductor (mm)Maximum Resistance per kilometre at 20 °C (Ω)Approximate Breaking Load (kN)Approximate Overall Diameter of Covered Conductor (mm)Approximate Mass per kilometre of Covered Conductor (kg)
AluminumSteelType 8Type 16
256/2.361/2.367.081.0939.6110.7190
506/3.351/3.3510.050.542618.3514.1330
1006/4.727/1.5714.150.273332.7018.2550
15030/2.597/2.5918.130.182869.2022.2920
15018/3.351/3.3516.750.181535.7020.8680
17530/2.797/2.7919.530.157679.8023.61050
17518/3.611/3.6118.050.156341.1022.1780
20030/3.007/3.0021.000.136392.2525.01190
20018/3.861/3.8619.300.136746.5523.3870

PVC Covered Conductor BS 6485,BS 7884 CU/PVC

Nominal cross-sectional area (mm²)Stranding and Wire Diameter (mm)Approximate Overall Diameter of Bare Conductor (mm)Maximum Resistance per kilometre at 20 °C (Ω)Approximate Breaking Load (kN)Approximate Overall Diameter of Covered Conductor (mm)Approximate Mass per kilometre of Covered Conductor (kg)
Type 8Type 16Type 8Type 16
147/1.604.801.3035.7446.88.4160190
163/2.655.701.1066.5907.79.3180220
323/3.758.060.552012.7110.512.1350390
357/2.507.500.533714.0979.911.5360400
707/3.5510.650.264626.8813.514.7690750
1007/4.3012.900.181037.6415.716.99901060

 

 

PVC Covered Conductor BS 6485,BS 7884 COPPER-ALLOY/PVC

Nominal cross-sectional area (mm²)Stranding and Wire Diameter (mm)Approximate Overall Diameter of Bare Conductor (mm)Maximum Resistance per kilometre at 20 °C (Ω)Approximate Breaking Load (kN)Approximate Overall Diameter of Covered Conductor (mm)Approximate Mass per kilometre of Covered Conductor (kg)
Type 16Type 16
123/2.304.951.7807.208.2170
227/2.006.001.01112.949.6270
387/2.607.800.598321.6911.8430
757/3.7011.100.295440.2315.1810
12519/2.9014.500.178468.7518.51310
15019/3.2016.000.146582.1620.01570

PVC Covered Conductor BS 6485,BS 3242 AAAC/PVC

Nominal cross-sectional area (mm²)Stranding and Wire Diameter (mm)Approximate Overall Diameter of Bare Conductor (mm)Maximum Resistance per kilometre at 20 °C (Ω)Approximate Breaking Load (kN)Approximate Overall Diameter of Covered Conductor (mm)Approximate Mass per kilometre of Covered Conductor (kg)
Type 16Type 16
257/2.347.021.0948.4410.6170
507/3.309.900.549816.8013.9280
1007/4.6513.950.276933.3018.0470
15019/3.4817.400.183050.6521.4680
20019/3.7618.800.156859.1022.8780