NA2XSY、NA2XSEY(YJLV) 3.6-6(7.2)kV (AL/XLPE/CTS/PVC)

Medium voltage cables for distribution networks; also for connection to generation units and plant and process connection. To be laid directly in ground, outdoors, indoors and in cable ducts. IEC 60502-2

Application

Our NA2XSY – YJLV cable is designed for medium voltage distribution networks. You can install this versatile cable in various settings. It is suitable for indoor use, in tunnels, and in cable trenches. You can also lay it directly in shafts or bury it underground. This cable is ideal for transformer stations and power plants. Industrial plants also benefit from its use. The cable is built to withstand mechanical pressures and certain pulling forces during installation and service.

Description

The NA2XSY – YJLV cable from Gongniu Cable features a robust construction for dependable performance.

  • Conductor: The cable uses circular compacted aluminum conductors (Class 2). This ensures efficient electrical transmission.
  • Insulation: Cross-Linked Polyethylene (XLPE) provides the main insulation. XLPE offers excellent electrical properties and can handle high temperatures.
  • Screening System:
    • A non-metallic, semi-conducting compound serves as the conductor screen.
    • Another non-metallic, semi-conducting compound acts as the insulation screen.
    • A Copper Tape Screen (CTS) provides the metallic screen. This system helps maintain a uniform electric field and enhances safety.
  • Outer Sheath: A tough Polyvinyl Chloride (PVC) outer sheath protects the cable. This sheath offers good resistance to grease, oil, and abrasion. It also provides mechanical protection.

This cable offers good electrical and mechanical properties. It features minimal dielectric loss and high insulation resistance.

Specification

  • Standards: This cable meets international standards for quality and performance.
    • IEC 60228: For the conductors of insulated cables.
    • IEC 60502-2: For power cables with extruded insulation for rated voltages from 1kV (UmU_m=1.2kV) up to 30kV (UmU_m=36kV).
  • Voltage Rating: Suitable for medium voltage networks as specified in IEC 60502-2.
  • Construction Elements: Aluminum / XLPE Insulation / Copper Tape Screen / PVC Sheath.

 

Technical Parameter

NA2XSY、NA2XSEY (YJLV) 3.6-6(7.2)kV IEC 60502-2

No. of Cores and Nominal Cross Section (mm²)Min. Number of WiresNominal Insulation Thickness (mm)Nominal Copper Tape Thickness (mm)Nominal Sheath Thickness (mm)Approx. Overall Diameter (mm)Approx. Weight (kg/km)Max. DC Resistance of Conductor at 20℃ (Ω/km)
No.
1X2562.50.121.517.13421.20
1X3562.50.121.518.13910.868
1X5062.50.121.619.44570.641
1X70122.50.121.621.15520.443
1X95152.50.121.723.16740.320
1X120152.50.121.724.37660.253
1X150152.50.121.826.08840.206
1X185302.50.121.827.710230.164
1X240302.60.121.930.412570.125
1X300302.80.122.033.215120.100
1X400533.00.122.136.518530.0778
1X500533.20.122.240.522830.0605
1X630533.20.122.344.427880.0469
Scroll to Top

Leave a message