Covered Cable

Application

Gongniu Cable’s covered cables are engineered for aerial installations. These cables primarily facilitate the overhead distribution of electrical energy under typical operating conditions. They are suitable for systems with voltages ranging from 13.8 kV up to 34.5 kV. It is important to understand that these products are classified as covered conductors, which means they do not carry an inherent voltage rating. For optimal safety and functionality, installers must mount these conductors on insulators or spacers that are appropriate for the specific service voltage of the system. Gongniu Cable advises users to meticulously evaluate the dielectric compatibility of the cable covering with the chosen insulators and spacers during the planning and installation phases.

Description

Our covered cables incorporate stranded, circular compressed aluminum conductors, ensuring efficient electrical transmission. A black, extruded semi-conducting shield functions as the conductor screen, enhancing the cable’s performance. The inner insulation layer predominantly features natural-colored thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE). Similarly, the outer insulation layer employs thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE). This robust outer layer, available from Gongniu Cable in black or grey, offers excellent resistance to weather elements and UV radiation.

Specifications

Gongniu Cable manufactures its covered cables in compliance with the ABNT NBR 11873 standard, which pertains to Covered Cables With Polymeric Material for Overhead Distribution Lines in Spacers. These cables possess a rating for normal service temperatures of either 75°C or 90°C, accommodating different operational environments. The product specifications cover constructions using both thermoplastic and cross-linked polyethylene materials. The designed operational voltage range for these covered cables extends from 13.8 kV up to 34.5 kV.

Technical Parameter

Covered Cable NBR 11873 15kV AAC/XLPE

Nominal section (mm²)Min. No. of WiresMax. DC Resistance at 20 °C (Ω/km)Nominal Insulation Thickness (mm)Cable Diameter (mm)Min. Breaking Load (daN)Weight (kg/km)
No.
3560.8683.013.0455185
5060.6413.014.1650227
70120.4433.015.8910298
95150.3203.017.61235384
120150.2533.018.81560459
150150.2063.020.51950546
185300.1643.022.12405658
240300.1253.024.43120834
300300.1003.026.539001018

 

 

Covered Cable NBR 11873 25kV AAC/XLPE

Nominal section (mm²)Min. No. of WiresMax. DC Resistance at 20 °C (Ω/km)Approx. Screen Thickness (mm)Nominal Insulation Thickness (mm)Cable Diameter (mm)Min. Breaking Load (daN)Weight (kg/km)
No.
3560.8680.54.016.2455260
5060.6410.54.017.3650309
70120.4430.54.019.0910389
95150.3200.54.020.81235485
120150.2530.54.022.01560566
150150.2060.54.023.71950662
185300.1640.54.025.32405783
240300.1250.54.027.63120972
300300.1000.54.029.739001167

 

 

Covered Cable NBR 11873 35kV AAC/XLPE/HDPE

Nominal section (mm²)Min. No. of WiresMax. DC Resistance at 20 °C (Ω/km)Approx. Screen Thickness (mm)Nominal Insulation Thickness (mm)Cable Diameter (mm)Min. Breaking Load (daN)Weight (kg/km)
No.
70120.4430.67.626.5910653
95150.3200.67.628.31235770
120150.2530.67.629.51560865
150150.2060.67.631.21950981
185300.1640.67.632.824051120
240300.1250.67.635.131201335
300300.1000.67.637.239001555