NYY (KVV)

This product is applicable to AC rated voltage U0/U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.

Application
This product is applicable to AC rated voltage U0/U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.

Construction
● Conductor: Conductor: Copper, class 1, 2, or 5, solid, stranded round or soft conductor
● Insulation: Polyvinyl chloride PVC
● Filler: Non-hygroscopic material
● Binder: Non-hygroscopic material
● Outer sheath: Polyvinyl chloride PVC

Chaircteritics
Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion. 

Specification
IEC 60228 Conductors of Insulate Cables 
IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) – Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)

Technical Parameter

No. of Cores and Nominal Cross SectionConductor TypeNominal Insulation Thickness Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. WeightMax. D.C. Resistance of Conductor
at 20℃ 
No. × mm² mmmmmmkg/kmΩ/km
2×0.520.61.88.17436.0
2×0.7520.61.88.58924.5
2×120.61.88.99818.1
2×1.520.81.810.313112.1
2×2.520.81.811.11577.41
2×421.01.813.02174.61
2×621.01.814.12653.08
2×1021.01.815.93831.83
3×0.520.61.88.48836.0
3×0.7520.61.88.910924.5
3×120.61.89.312118.1
3×1.520.81.810.815412.1
3×2.520.81.811.71927.41
3×421.01.813.72724.61
3×621.01.814.93483.08
3×1021.01.816.85051.83
4×0.520.61.89.09736.0
4×0.7520.61.89.511324.5
4×120.61.89.913818.1
4×1.520.81.811.619112.1
4×2.520.81.812.62407.41
4×421.01.814.93444.61
4×621.01.816.24453.08
4×1021.01.818.46641.83
5×0.520.61.89.611036.0
5×0.7520.61.810.114324.5
5×120.61.810.616118.1
5×1.520.81.812.522012.1
5×2.520.81.813.62857.41
5×421.01.816.24124.61
5×621.01.817.65233.08
5×1021.01.820.17991.83
6×0.520.61.810.212436.0
6×0.7520.61.810.814724.5
6×120.61.811.417018.1
 
No. of Cores and Nominal Cross SectionConductor TypeNominal Insulation Thickness Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. WeightMax. D.C. Resistance of Conductor
at 20℃ 
No. × mm² mmmmmmkg/kmΩ/km
6×1.520.81.813.523912.1
6×2.520.81.814.73117.41
6×421.01.817.64554.61
6×621.01.819.25963.08
6×1021.01.821.98681.83
7×0.520.61.810.213136.0
7×0.7520.61.810.815724.5
7×120.61.811.418218.1
7×1.520.81.813.525912.1
7×2.520.81.814.73417.41
7×421.01.817.65044.61
7×621.01.819.26573.08
7×1021.01.821.99621.83
8×0.520.61.811.115036.0
8×0.7520.61.811.918024.5
8×120.61.812.520918.1
8×1.520.81.814.929812.1
8×2.520.81.816.43927.41
8×421.01.819.65824.61
8×621.01.821.57553.08
8×1021.01.824.611111.83
9×0.520.61.811.916736.0
9×0.7520.61.812.720324.5
9×120.61.813.423518.1
9×1.520.81.816.033412.1
9×2.520.81.817.64427.41
9×421.01.821.26554.61
9×621.01.823.28573.08
9×1021.01.826.712611.83
10×0.520.61.812.317936.0
10×0.7520.61.813.121624.5
10×120.61.813.925218.1
10×1.520.81.816.736012.1
10×2.520.81.818.34787.41
10×421.01.822.17114.61
 
No. of Cores and Nominal Cross SectionConductor TypeNominal Insulation Thickness Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. WeightMax. D.C. Resistance of Conductor
at 20℃ 
No. × mm² mmmmmmkg/kmΩ/km
10×621.01.824.39323.08
10×1021.01.827.913691.83
12×0.520.61.812.619536.0
12×0.7520.61.813.523824.5
12×120.61.814.328018.1
12×1.520.81.817.240612.1
12×2.520.81.818.95437.41
12×421.01.822.88164.61
12×621.01.825.110723.08
14×0.520.61.813.221736.0
14×0.7520.61.814.126624.5
14×120.61.814.931418.1
14×1.520.81.818.045912.1
14×2.520.81.819.86177.41
14×421.01.824.09324.61
14×621.01.826.312303.08
16×0.520.61.813.824236.0
16×0.7520.61.814.829824.5
16×120.61.815.635218.1
16×1.520.81.818.951612.1
16×2.520.81.820.96967.41
16×421.01.825.310554.61
16×621.01.827.813933.08
19×0.520.61.814.427136.0
19×0.7520.61.815.533624.5
19×120.61.816.440018.1
19×1.520.81.819.959212.1
19×2.520.81.822.08027.41
19×421.01.826.712224.61
19×621.01.929.916433.08
20×0.520.61.815.128636.0
20×0.7520.61.816.235524.5
20×120.61.817.242218.1
20×1.520.81.820.962412.1
20×2.520.81.823.18457.41
 
No. of Cores and Nominal Cross SectionConductor TypeNominal Insulation Thickness Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. WeightMax. D.C. Resistance of Conductor
at 20℃ 
No. × mm² mmmmmmkg/kmΩ/km
20×421.01.828.212884.61
20×621.01.931.517313.08
21×0.520.61.815.129436.0
21×0.7520.61.816.236624.5
21×120.61.817.243618.1
21×1.520.81.820.964712.1
21×2.520.81.823.18797.41
21×421.01.828.213424.61
21×621.01.931.518043.08
22×0.520.61.815.830936.0
22×0.7520.61.817.038524.5
22×120.61.818.045818.1
22×1.520.81.822.067912.1
22×2.520.81.824.49227.41
22×421.01.930.214304.61
22×621.02.033.519083.08
24×0.520.61.816.533836.0
24×0.7520.61.817.842024.5
24×120.61.818.850018.1
24×1.520.81.823.073912.1
24×2.520.81.825.610067.41
24×421.01.931.715594.61
24×621.02.035.120843.08
27×0.520.61.816.836236.0
27×0.7520.61.818.145324.5
27×120.61.819.254218.1
27×1.520.81.823.580812.1
27×2.520.81.826.111047.41
27×421.02.032.617324.61
27×621.02.136.123143.08
30×0.520.61.817.439236.0
30×0.7520.61.818.749324.5
30×120.61.819.959218.1
30×1.520.81.824.388512.1
30×2.520.81.827.012127.41
 
No. of Cores and Nominal Cross SectionConductor TypeNominal Insulation Thickness Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. WeightMax. D.C. Resistance of Conductor
at 20℃ 
No. × mm² mmmmmmkg/kmΩ/km
30×421.02.033.819034.61
30×621.02.137.425473.08
33×0.520.61.818.042636.0
33×0.7520.61.819.453724.5
33×120.61.820.664418.1
33×1.520.81.825.396512.1
33×2.520.81.828.113257.41
33×421.02.035.120814.61
33×621.02.239.128043.08
37×0.520.61.818.646436.0
37×0.7520.61.820.158724.5
37×120.61.821.370718.1
37×1.520.81.826.2106412.1
37×2.520.81.929.714857.41
37×421.02.136.723204.61
37×621.02.240.631083.08
44×0.520.61.820.754936.0
44×0.7520.61.822.469424.5
44×120.61.823.883618.1
44×1.520.81.929.9128012.1
44×2.520.82.033.517747.41
44×421.02.241.427664.61
44×621.02.446.137283.08
48×0.520.61.821.058136.0
48×0.7520.61.822.773924.5
48×120.61.824.289318.1
48×1.520.81.930.4137212.1
48×2.520.82.034.019067.41
48×421.02.342.329984.61
48×621.02.446.940173.08
52×0.520.61.821.662136.0
52×0.7520.61.823.379124.5
52×120.61.824.895718.1
52×1.520.81.931.2147312.1
52×2.520.82.035.020487.41
52×421.02.343.532254.61
52×621.02.448.243263.08
 
No. of Cores and Nominal Cross SectionConductor TypeNominal Insulation Thickness Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. WeightMax. D.C. Resistance of Conductor
at 20℃ 
No. × mm² mmmmmmkg/kmΩ/km
52×621.02.448.243263.08
61×0.520.61.822.871136.0
61×0.7520.61.824.790924.5
61×120.61.826.3110218.1
61×1.520.82.033.3171412.1
61×2.520.82.137.323867.41
61×421.02.446.437564.61
61×621.02.651.650653.08